XO Communications’ Memphis data center is located at 5127 Truse Road, 1st floor, Memphis, TN 38117. The data center building has 10 feet ceiling heights and provides secure loading docks, with on site parking available.
The data center offers Memphis colocation space through full size secured locking cabinets and customized cage space. The data center is regularly audited in accordance with SSAE 16 SOC 3 requirements, also offering solutions that meet the rigorous compliance standards for HIPAA, PCI and SOX 404. The data center provides excellent security measures with onsite security officers, 24×7 Closed Circuit Televisions (CCTV), Open Sound Control (OSC) monitoring system, with secure entry through the use of biometric authentication and key card access control systems. All access in the data center is remotely monitored by the XO NOC. The data center is equipped with FM 200 gas based fire suppression systems that are located throughout the facility to meet any fire emergency.
The Memphis data center provides a reliable power infrastructure with single feed AC commercial power services. The entire critical infrastructure is protected by a UPS system with two battery strings capable of providing 9 minutes of backup power at full load in the event there is a loss of utility power. Standby diesel generators that are connected to an automatic transfer switch (ATS) provide emergency power for prolonged power outages. The generators are test run on a weekly basis and full load tested on a monthly basis, and has on site fuel storage for up to 24 hours of continuous runtime. The data center power room is separated from the technical space with diverse power delivered by multiple PDUs in a true A+B design to each cabinet, and provides a power density of 4kW per cabinet or 160 watts per square foot. The data center provides DC power options designed with greater than 4 hours of battery reserves on multiple N+1 battery strings. The entire power infrastructure has monthly preventive maintenance performed and semi-annual comprehensive maintenance. The HVAC units maintained via air cooled precision cooling system in N+1 redundant configuration effectively controls the cooling and humidity in the data center. The HVAC units have monthly preventive maintenance performed and quarterly comprehensive maintenance performed.
XO Communications’ 5127 Truse Road data center is a carrier neutral facility with private network connectivity options. The facility has switched and dedicated access to transport facilities via high-capacity metropolitan and long haul XO network facilities. The data center has a fully redundant network infrastructure offering 100% SLA on network and server availability. The data center provides VLANs, customized firewalls, site to site VPN, IDS/IPS, load balancing and multicast. The on site staff provides help desk support services, and remote hands services.
About XO
Memphis, TN 38117
View all XO data center locations. You may also view all data centers in Memphis, or expand your search to all Tennessee data centers.
XO Communications – Memphis Data Center Highlights
- Secure Loading Docks
- Onsite Parking Available
- Slab on Grade Floor
- 10 Feet Ceiling Height
- Colocation
- Full Size Secured Locking Cabinets
- Customized Cage Space
- Compliance and Certifications
- SSAE 16 SOC 3
- HIPAA
- PCI
- SOX 404
- Security
- Onsite Security Officers
- 24×7 Closed Circuit Televisions (CCTV) and Open Sound Control (OSC) Monitoring System
- Biometric Authentication
- Key Card Access Control System
- Remotely Monitored by XO NOC
- FM 200 Gas Based Fire Suppression System
- Single Feed AC Commercial Power Services
- UPS System with Two Battery Strings Providing 9 Minutes of Backup Time
- Standby Diesel Generators
- Fuel Storage Onsite for 24 Hours of Continuous Runtime
- Generators Test Run On Weekly Basis and Full Load Tested on Monthly Basis
- Automatic Transfer Switch (ATS)
- Data Center Power Room is Separated From Technical Space
- Multiple PDUs
- Dual Distribution Paths in True A+B Feeds
- Power Density
- 4 kW Per Cabinet
- 160 Watts Per Square Feet
- DC Power System
- Designed for Greater Than 4 Hours of Battery Reserves
- Multiple N+1 Battery Strings
- Power Infrastructure Maintenance
- Monthly Preventive Maintenance
- Semi-Annual Comprehensive Maintenance
- HVAC Units Maintained Via Air Cooled Precision Cooling System in N+1 Redundant Configuration
- HVAC Maintenance
- Monthly Preventive Maintenance
- Quarterly Comprehensive Maintenance
- Carrier Neutral Facility
- Fully Redundant Network Infrastructure
- 100% SLA on Network and Server Availability
- Helpdesk and Support Services
- Remote Hands Services