XO Communications’ Austin data center is located at 11501 Domain Drive, Suite 100 in Building 5, Austin, TX 78758, and is one of the two facilities that is owned and operated by XO Communications in Austin. The data center provides secure loading docks with on site parking available.
The data center offers colocation space through full size secured locking cabinets and customized cage space. The data center is regularly audited in accordance with SSAE 16 SOC 3 requirements, and also offers solutions that meet the rigorous compliance standards for HIPAA, PCI and SOX 404. The data center provides excellent security measures such as on site security officers, 24×7 closed circuit televisions (CCTV) and open sound control (OSC) monitoring system, and has a secure entry through the use of biometric authentication and key card access control system. All the access in the data center is remotely monitored by XO NOC. The data center is equipped with double interlocked pre action fire suppression system that are located throughout the facility to meet any fire emergency.
The Austin data center provides a reliable power infrastructure with single feed AC commercial power services. The entire critical infrastructure is protected by a UPS system with two battery strings capable of providing 9 minutes of backup power at full load in the event there is a loss of utility power. Standby diesel generators that are connected to an automatic transfer switch (ATS) provide emergency power for prolonged power outages. The generators are test run on a weekly basis and full load tested on a monthly basis, and has on site fuel storage for up to 24 hours of continuous runtime. The data center power room is separated from the technical space with diverse power delivered by multiple PDUs in a true A+B design to each cabinet, and provides a power density of 4kW per cabinet or 160 watts per square foot. The data center provides DC power options designed with greater than 4 hours of battery reserves on multiple N+1 battery strings. The entire power infrastructure has monthly preventive maintenance performed and semi-annual comprehensive maintenance. The HVAC units maintained via air cooled precision cooling system in N+1 redundant configuration effectively controls the cooling and humidity in the data center. The HVAC units have monthly preventive maintenance performed and quarterly comprehensive maintenance performed.
XO Communications’ 11501 Domain Drive data center is a carrier neutral facility with connectivity option to a private network. The facility has switched and dedicated access to transport facilities via high-capacity metropolitan and long haul XO network facilities. The data center has a fully redundant network infrastructure offering 100% SLA on network and server availability. The data center provides VLANs, customized firewalls, site to site VPN, IDS/IPS, load balancing and multicast. The on site staff provides help desk support services, and remote hands services.
About XO
Austin, TX 78758
View all XO data center locations. You may also view all data centers in Austin, or expand your search to all Texas data centers.
XO Communications – Austin Data Center #2 Highlights
- Secure Loading Docks
- Onsite Parking Available
- Slab on Grade Floor
- Built Up Roof Style
- Colocation
- Full Size Secured Locking Cabinets
- Customized Cage Space
- Compliance and Certifications
- SSAE 16 SOC 3
- HIPAA
- PCI
- SOX 404
- Security
- Onsite Security Officers
- 24×7 Closed Circuit Televisions (CCTV) and Open Sound Control (OSC) Monitoring System
- Biometric Authentication
- Key Card Access Control System
- Remotely Monitored by XO NOC
- Double Interlocked Pre Action Fire Suppression System
- Single Feed AC Commercial Power Services
- UPS System with Two Battery Strings Providing 9 Minutes of Backup Time
- Standby Diesel Generators
- Fuel Storage Onsite for 24 Hours of Continuous Runtime
- Generators Test Run On Weekly Basis and Full Load Tested on Monthly Basis
- Automatic Transfer Switch (ATS)
- Data Center Power Room is Separated From Technical Space
- Multiple PDUs
- Dual Distribution Paths in True A+B Feeds
- Power Density
- 4 kW Per Cabinet
- 160 Watts Per Square Feet
- DC Power System
- Designed for Greater Than 4 Hours of Battery Reserves
- Multiple N+1 Battery Strings
- Power Infrastructure Maintenance
- Monthly Preventive Maintenance
- Semi-Annual Comprehensive Maintenance
- HVAC Units Maintained Via Air Cooled Precision Cooling System in N+1 Redundant Configuration
- HVAC Maintenance
- Monthly Preventive Maintenance
- Quarterly Comprehensive Maintenance
- Carrier Neutral Facility
- Fully Redundant Network Infrastructure
- 100% SLA on Network and Server Availability
- Helpdesk and Support Services
- Remote Hands Services