TierPoint’s Nashville data center is located at 311 Eddy Ln, Franklin, TN 37064. The Nashville data center is designed to ensure that critical IT system, applications, and data are safe from fires, earthquakes and other disasters.
Nashville data center is a Tier I infrastructure. The colocation services are provided through half and full cabinets. Nashville data center is SSAE 16 SOC I Type II certified facility. The data center has a very reliable and scalable power infrastructure. The immediate power failure is protected by UPS system with battery bank. The diesel generator provides the backup facility on the loss of utility power. The N+1 configured HVAC system effectively moderate the cooling and humidity for the IT performance of all IT equipment.
Nashville data center is a carrier neutral facility, and provides redundant fiber connectivity. The network infrastructure is Cisco certified core network, and access to TierPoint MPLS network. TierPoint utilize Internet and MPLS connectivity via multiple fiber routes in and out of colocation, as well as diverse paths to the Internet. The data center has also remote hands/eye support for customers’ equipment.
About TierPoint
Franklin, TN 37064
View all TierPoint data center locations. You may also view all data centers in Franklin, or expand your search to all Tennessee data centers.
TierPoint – Nashville Data Center Highlights
- Tier III Modular Design
- Located Outside Severe Weather and Seismic Zone
- Rated to Withstand Hurricane Force Winds
- Ballistic Resistant Walls, Doors, and Windows
- SSAE 16 SOC I Type II Certified Facility
- Cabinets and Caged Space Solutions
- 22,000 Square Feet of Data Center
- 10,000 Square Feet of 24 and 36 Inches Raised Floor
- Physical Security and Video Surveillance 24 x 7 x 365
- Biometric Scanner and Key Card Authentication Entry
- Double Mantrap Facility
- LEED Gold Certified Design
- Targeted PUE between 1.2 and 1.5
- 2,500 kVA of Utility Capacity
- 2N Power Design
- A and B Methodology Power Distribution
- 8 x Dual Sourced 300 kVA STS PDUs
- 2 x 1,20 kVA APC UPS
- 2 x 2000 kW Cummings Diesel Generators
- N+1 Configured Cooling Redundancy
- 4 x 120 Tons Roof Top Air Handler
- Hot Aisle/Cold Aisle Cooling Design
- Properly Grounded Equipment
- Foreseer and JACE Building Management System
- Pre Action Double Interlock Dry Pipe Fire Suppression System
- VESDA Control
- Carrier Neutral
- Access to Windstream MPLS Network
- 24 x 7 x 365 Network Operation Center
- Remote Hands