SunGard Dallas data center (DAL-3001) is located at 3001 Red Hawk Drive, Grand Prairie, TX 75052. Private meeting rooms are available for group meetings, conversations and planning. A shared break room is available inside the facility and many restaurants are available within a couple of miles of the center. This business continuity data center offers workforce continuity services.
The data center has implemented the ISO certified procedure and controls. 24 to 30 inches raised flooring provides underfloor cooling and power distribution. The data center security features 24 x 7 onsite security staff, CCTV video and infrastructure monitoring, locked cabinet and cages, and is biometric and multi-level key card secured.
Grand Prairie data center provides full power redundancy from N+1 up to 2N+1, and offers 100% SLA on power. The immediate power failure is protected by dual UPS system. The standby power is provided by catalytic reduction equipped generators. The data center uses ASCO Automatic Transfer Switch (ATS). The cooling and humidity in the data center is controlled by N+1 chiller system and N+1 CRAC units including variable speed, impeller cooling system. The data center provide 12 feet ceilings with closed plenum hot air return, and hot and cold aisle cabinet design provides efficient cooling. The facility uses automated power monitoring and management system.
The data center is a carrier neutral facility with connectivity to multiple service providers. The data center provides meshed, multi-vendor Internet transit connectivity, diverse path long haul access (public or private), redundant internal network distribution platforms and dual customer physical handoffs (Copper, single-mode and multi-mode fiber). 24 x 7 x 365 onsite NOC provides the support and helpdesk services to its customers.
About Sungard
Dallas, TX 75052
View all Sungard data center locations. You may also view all data centers in Dallas, or expand your search to all Texas data centers.
SunGard – Dallas Data Center (DAL-3001) Highlights
- Private Conference Rooms
- Common Break Room
- ISO Certified Procedure and Controls
- 24 to 30 Inches Raised Flooring
- Security
- 24 x 7 Onsite Security
- CCTV Video and Infrastructure Monitoring
- Locked Cabinet and Cages
- Biometric Scan
- Multi-Level Key Card
- 100% SLA On Power
- N+1 upto 2N+1 Power Infrastructure
- Dual UPS System
- Catalytic Reduction Equipped Generators
- N+1 Chiller System and N+1 CRAC Units
- 12 Feet Ceilings with Closed Plenum Hot Air Return
- Hot and Cold Aisle Cabinet Design
- Automated Power Monitoring and Management System
- Carrier Neutral Facility
- Meshed, Multi-Vendor Internet Transit Connectivity
- Diverse Path Long Haul Access (Public Or Private)
- Redundant Internal Network Distribution Platforms
- Dual Customer Physical Handoffs (Copper, Single-Mode And Multi-Mode Fiber)
- 24 x 7 x 365 Onsite NOC