INAP’s Seattle data center (SEF) is located at 140 4th Ave., N Suite 200 Seattle, WA 98109. The facility is located in the heart of downtown Seattle and has convenient access to airports, highways, and hotels. The data center built in 1999 has seismic zone 3 rating and outside the flood plain. The building is structural steel and reinforced concrete construction. The data center has loading docks and roof rights availability. The facility provides amenities like fully equipped office space, conference room, technical workspace and adjacent breakdown rooms, and full service lounge.
The data center offers a number of colocation options, including cabinets in half and full sizes, and custom private caged space. INAP uses Chatsworth Products’ 4-Post QuadraRack ServerFrame which provides a highly secure storage environment. The data center provides 26,000 square feet of colocation space, and 10.5 feet of clear ceiling height. 20 inches antistatic raised floor provides the efficient cooling and easy management of cabling system. The facility is regularly audited in accordance with SSAE 16 Type II requirements. The data center provides the state of the art security measures, including 24x7x365 security guards onsite, CCTV monitoring through 16 x motion detection cameras with archiving of data for 90 days, and intrusion detection system. The entrance to the data center floor is authenticated through the use of card key and biometric scan. The facility uses multi zone pre action dry pipe fire suppression system for the life safety. The facility has smoke and heat detection facility and is remotely monitored.
Seattle (SEF) data center is a reliable and fault tolerant N+1 power infrastructure with concurrently maintainable power system. The power to the data center is delivered through redundant power feeds by Seattle City Light. The entire critical infrastructure is protected by 14 x 225 kVA MGE UPS system in N+1 redundancy on power failure. The secondary power is provided by 4 x 1.5 MW Caterpillar diesel generators onsite. The data center provides single and three-phase AC and 48V DC power to the customers’ equipment. The DC battery bank provides 8 minutes of backup time on full load. The cooling and humidity in the data center is maintained by 20 x 30 tons cooling units in N+1 configuration. The hot aisle, cold aisle separation and passive cooling solutions maximize cooling efficiencies.
140 4th Ave. is a carrier neutral facility with robust carrier neutral meet-me-room, including alternative transit and local access options. The data center offers 100% network uptime SLA. INAP’s multi-homed route optimized Performance IP provides links up to 10GB through multiple top tier carriers. The data center has switched layer 2 network connectivity from SJE011 to 11 Great Oaks Blvd. via a resilient, INAP managed metropolitan network. 24x7x365 NOC staff provides the helpdesk and support services, and remote hands services.
About INAP
Seattle, WA 98109
View all INAP data center locations. You may also view all data centers in Seattle, or expand your search to all Washington data centers.
INAP – Seattle Data Center (SEF) Highlights
- Located in the Heart of Downtown Seattle
- Convenient Access to Airports, Highways and Hotels
- Built in 1999
- Seismic Zone 3 Rating
- Outside the Flood Plain
- Structural Steel and Reinforced Concrete Construction
- Loading Docks
- Roof Rights Availability
- Amenities
- Fully Equipped Office Space
- Conference Room
- Technical Workspace and Adjacent Breakdown Rooms
- Full Service Lounge
- Colocation
- Cabinets in Half and Full Sizes
- Custom Private Caged Space
- Chatsworth Products’ 4-Post Quadrarack Serverframe
- 26,000 Square Feet of Colocation Space
- 10.5 Feet of Clear Ceiling Height
- 20 Inches Antistatic Raised Floor
- SSAE 16 Type II Certified
- Security
- 24x7x365 Security Guards Onsite
- CCTV Monitoring with Archiving of Data for 90 Days
- 16 x Motion Detection Cameras
- Intrusion Detection System
- Card Key Access
- Biometric Scan
- Fire Detection and Suppression
- Multi Zone Pre Action Dry Pipe Fire Suppression System
- Smoke and Heat Detection Facility
- Remotely Monitored
- N+1 Power Infrastructure
- Redundant Power Feeds
- 14 x 225 kVA MGE UPS System in N+1 Redundancy
- 4 x 1.5 MW Caterpillar Diesel Generators Onsite
- 48V DC Power
- DC Battery Bank with 8 Minutes of Backup Time
- Power Density of 18 kW Per Rack
- HVAC Units in N+1 Configuration
- 20 x 30 Tons Cooling Units
- Hot Aisle Cold Aisle Design
- Carrier Neutral Facility
- 100% Network Uptime SLA
- 24x7x365 NOC Staff
- Remote Hands Services