Global Access Point’s DEC building South Bend data center is located at 4001 Technology Dr., South Bend, IN 46628. The data center location also provides reduced risks in terms of geopolitical concerns, earthquakes, hurricanes and tornados. The data center has wireless capabilities, high speed Internet, shared conference rooms with video conferencing, ample parking space, and elevator access.
The data center offers half cabinet or full cabinet colocation, rack space, 10 x 10 feet of caged space, and private suites. The data center provides 15,000 square feet of space including 5,000 square feet of raised floor space. The data center provides 24 x 7 x 365 security staff, video surveillance, and card key entry. FM200 fire suppression is installed in the data center for suppressing any fire spark in the data center.
The data center has a very reliable power infrastructure with 0.57 MVA of power is served to the facility. The emergency power supply is provided by UPS system that is backed by diesel generators. Tenants have the ability to bring redundant ‘A’ and ‘B’ power feeds into their space, cage, or cabinet. The data center provides 120V, 208V single phase and 208V three phase AC power, and 48V DC power with 8 hours of battery backup. HVAC units effectively controls cooling and humidity in the data center.
DEC building data center is a carrier neutral facility, and provides access to four telecommunication companies who touch the Global Access Point network in South Bend, Chicago, and Indianapolis. The building is outfitted with 4 entrance paths for cable and fiber in order to meet the diverse needs of the carriers as well as take advantage of the high density of fiber optic that runs through the South Bend.
About Global Access Point
South Bend, IN 46628
View all Global Access Point data center locations. You may also view all data centers in South Bend, or expand your search to all Indiana data centers.
Global Access Point – South Bend Data Center Highlights
- Reduced Risks in Terms of Geopolitical Concerns
- Earthquakes
- Hurricanes
- Tornados
- Facilities
- Wireless Capabilities
- High Speed Internet
- Shared Conference Rooms with Video Conferencing
- Ample Parking Space
- Elevator Access
- Colocation
- Half Cabinet
- Full Cabinet
- 10 x 10 Feet of Caged Space
- Private Suites
- 15,000 Square Feet of Space
- 5,000 Square feet of Raised Floor
- 24 X 7 X 365 Security Staff
- Video Surveillance
- Card Key Entry
- FM200 Fire Suppression
- 0.57 MVA Of Power
- UPS System
- Diesel Generators
- Redundant ‘A’ And ‘B’ Power Feeds
- 120V, 208V Single Phase
- 208V Three Phase AC Power
- 48V DC Power
- HVAC Units
- Carrier Neutral Facility
- Access to 4 Telecommunication Companies
- 4 Entrance Paths for Cable and Fiber in Building