Data Center West’s Eugene data center is located at 800 Willamette Street, Eugene, OR 97401. Data Center West offers flexible colocation space options including racks, half and full cabinets, and caged space of 8’x5′, 10’x7′, or 10’x8′ sizes. The data center uses seismically braced racks, and front and back individual locking cabinets.
The data center provides 500 square feet of space with floor load capacity of 800 lbs. per square feet. The facility provides ceiling height of 8′, roof rights availability, and overhead ladder rails for cable management. The security in the data center is provided through video surveillance, monitoring by NOC staff, and 24×7 secure access into the facility. The data center uses heat and smoke alarm for the early detection of fire.
The Eugene data center is a reliable infrastructure. The backup power to data center is provided by building service standby diesel generator onsite on the loss of utility power. The data center delivers 110V, 208V, and 220V dedicated electrical circuits to customer’s equipment, and also provides Telco DC power service. The multiple 5 tons air conditioning units maintain the humidity levels and cooling in the data center with constant monitoring.
Data Center West’s 800 Willamette Street data center is a carrier neutral facility with connectivity to multiple carriers. The data center provides cross connect services, dual entrances into facility through 3″ fiber conduit, clear line of sight, and OC-12 redundant fiber optic connections to Internet backbone. The 24x7x365 NOC staff provides the helpdesk and support services.
About Data Center West
Eugene, OR 97401
View all Data Center West data center locations. You may also view all data centers in Eugene, or expand your search to all Oregon data centers.
Data Center West – Eugene Data Center Highlights
- Colocation
- Racks
- Half and Full Cabinets
- Caged Space
- 8’x5′
- 10’x7′
- 10’x8′
- Seismically Braced Racks
- Front and Back Individual Locking Cabinets
- 500 Square Feet of Space
- Floor Load Capacity of 800 lbs. Per Square Feet
- Ceiling Height of 8′
- Roof Rights Availability
- Overhead Ladder Rails for Cable Management
- Security
- Video Surveillance
- Monitoring by NOC Staff
- 24×7 Secure Access
- Heat and Smoke Alarm
- Standby Building Service Diesel Generator Onsite
- 110V, 208V, and 220V Dedicated Electrical Circuits
- Telco DC Power Service
- Multiple 5 Tons Air Conditioning Units
- Carrier Neutral Facility
- Cross Connect Services
- Dual Entrances Into Facility Through 3″ Fiber Conduit
- Clear Line Of Sight
- OC-12 Redundant Fiber Optic Connections
- 24x7x365 NOC Staff